Brand : | | Schneider |
[Ii] instantaneous protection pick-up adjustment range : | 1.5xIr ~ 10xIr |
Ground-fault protection pick-up adjustment type Ig : | adjustable (for CB with earth fault protection) |
Ground-fault protection time delay adjustment type tg : | adjustable (for CB with earth fault protection) |
trip unit protection functions : | LI | LSI | LSIG |
Trip Unit Technology : | Electronic |
Mounting Type : | Fixed |
IP Degree of Protection : | IP40 |
CB Type : | | MCCB |
[Icu] rated ultimate short-circuit breaking capacity : | 30kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 / 50kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 / 50kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 / 85kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 / 40kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 |
Trip Unit Name : | Micrologic 2.0 | Micrologic 5.0 | Micrologic 5.0 A | Micrologic 5.0 E | Micrologic 6.0 | Micrologic 2.0 A | Micrologic 2.0 E |
[Ui] Rated Insulation Voltage : | 800V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity : | 30kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 / 40kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 / 50kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 / 50kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 / 50kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
[Icw] rated short-time withstand current : | 19.2kA 1s conforming to IEC 60947-2 |
Mechanical Durability : | 10000Cycles |
Electrical Durability : | 2000cycles at 690 V In / 4000 cycles at 690 V In/2 / 5000 cycles at 440 V In / 6000 cycles at 440 V In/2 |
Earth-leakage Potection : | Without |
Auxiliary Contact : | One (1) NO/NC |
Instantaneous protection pick-up adjustment type Ii : | Adjustable |
[tsd] Short-time protection delay adjustment range : | 0.1s~0.4s I²t=on / 0s~0.4 s I²t=off |
Number of Poles : | 3P | 4P |
Performance Level : | N 50 kA 415 V AC |
CB Model : | ComPact NS |
[Icu] Breaking Capacity : | 50kA |
(In) Rated Current : | 630A | 800A | 1000A | 1250A | 1600A |
[Ue] Rated Operational Voltage : | 690VAC |
Device Application : | Distribution |
Control Type : | Toggle | Rotary handle |
Rated Impulse Withstand Voltage (Uimp) : | 8kV conforming to IEC 60947-2 |
Network Type : | AC |
Long-time pick-up adjustment type Ir (thermal protection) : | Adjustable 9 settings |
[Ir] long-time protection pick-up adjustment range : | 0.4xIn ~ 1xIn |
Long-time protection delay adjustment type tr : | Adjustable 9 settings |
[tr] long-time protection delay adjustment range : | 12.5to600 s at 1.5 x Ir / 0.5to24 s at 6 x Ir / 0.7to16.6 s at 7.2 x Ir |
Short-time protection pick-up adjustment type Isd : | Adjustable 9 settings (for CB with S: short time short-circuit protection) |
[Isd] Short-time protection pick-up adjustment range : | 1.5xIr ~ 10xIr |
Short-time protection delay adjustment type tsd : | Adjustable (for CB with S: short time short-circuit protection) |
Ambient Air Temperature : | 25C to +70°C, 2000 m.a.s.l, up to 95% humidity- |